Interchange of HNP074 PALL Fluid Conditioning Purifier

Release date:2012-11-16 Author:LEFILTER




Reliability of systems, the service life of system components and fluids are extended by minimising water contamination.
The Pall HNP074 Purifier is designed to remove water from
fluids thereby maintaining lubricity properties, minimising fluid oxidation and reducing aeration.

Benefits of Pall HNP074 Purifier
• High performance water and gas removal
• Simple operation
• Extension of system fluid life
• Increased equipment reliability
• Minimised corrosion within systems
• Reduced fluid disposal
• reduce operating cost

Pall purifiers remove 100% of free water and in excess 80% of dissloved water.They also remove 100% of free gas and in excess 80% of dissloved gases.

The Pall HNP074 fluid conditioning purifier can be used as a fixed installation or portable unit that is easily removed and connected to any fluid system.
This purifier design is based on the existing range of Pall fluid conditioning products, it allows for easy operation and control.
Automated controls, integral to the unit constantly monitor the operation of the purifier and will safely shutdown the unit if acceptable limits are exceeded.

Specifications
Dimensions: 680x1997x1580mm (26.8"x78.6"x62.2")
Dry mass: 390kg (860 lbs)
Inlet connections: 2" BSPP or 2" NPT
Outlet connections: 11⁄2" BSPP or 11⁄2" NPT
Flow rate: 70 L/min (18.5 US gpm) at 50 Hz   84 L/min (22.2 US gpm) at 60 Hz
Inlet pressure: 3.0 bar g (300 kPa / 44 psig) maximum
System back pressure: 4.35 bar g (435 kPa / 63.4 psig) maximum
Fluid operating temperature: +10ºC to +70ºC (50°F to 158°F)
Fluid viscosity: 700 cSt (3300 SUS) maximum
Operating vacuum: -0.6 to -0.8 barg [adjustable]
Power supply: 400VAC, 50Hz or 480VAC, 60 Hz
Total Motor power: 6.4kW @ 50Hz / 8.5kW @ 60Hz


Materials of Construction
Base frame: Epoxy painted carbon steel
Vacuum vessel: 304 Stainless Steel
Fittings & fasteners: Corrosion protected carbon steel
Control box: Epoxy painted carbon steel
Hoses: Nitrile or Chlorinated polyethylene
Seals: Nitrile or Fluorocarbon
Note: Pall fluid conditioning purifiers comply with all relevant EC directives and bears the CE mark.

Ordering
Information
Purifier Part No: HNP074 0 *
Replacement Element Part No:
Replacement Air Breather Element:
Tabble 1
UE619
Tabble 3
HC0293SEE5
Tabble 2
Tabble 6
Tabble 3
Tabble 4
Tabble 4 Tabble 5
Table 1. Voltage
Code Voltage
M 220 VAC
S 400 VAC
U 440 VAC
W 480 VAC
Table 2. Frequency
Code Frequency
3 50Hz Ø3
4 60Hz Ø3
Table 4. Seal Type
Code Material
H Nitrile
Z Fluorocarbon
Table 3. Element Rating
Code Rating (μm) (ßx(c)³1000)**
AZ 2.5
AP 5
AN 7
AS 12
AT 22
Table 5. Mounting Options
Code  Mounting  Outlet Filter length (in)  Connections
 
C Mobile 20''   BSPP
N Static  20''   BSPP
A Mobile 40''   BSPP
B Static  40''   BSPP
X Mobile 20''  NPT
Y Static  20''  NPT
V Mobile 40''  NPT
W Static  40''  NPT
Table 6. Element length
Code  Nominal Length (in)
20          20
40          40
** Beta ratios are designated using the symbol (c) to signify they were measured using the ISO16889 procedure.